Guided Wave Testing Procedures
The MsS guided wave testing is performed by the following procedure:
- Identify and record the pipe (pipe section, pipeline, etc.). Verify.
- Clean the pipe. Wipe off any dirt or loose corrosion with a paper towel. If the surface is rough, use a wire brush or sandpaper to smooth the surface and then clean.
- Prepare the FeCo strip to fit the circumference of pipe
- Attach the strip around the pipe circumference using shear couplant, mechanical dry coupling, or epoxy bonding
- Condition the strip for torsional-mode operation
- A continuous probe covers the entire circumference of a pipe
- Excellent direction control
- Zero near-field length
- Place the MsS probe over the strip
- Connect MsS probe to MsS equipment
- Acquire data
- (Long term monitoring only) Find the best center frequency and wrap electric wires for that frequency operation
- (Long term monitoring only) Acquire baseline data for long-term monitoring after reinstalling insulation or recovering of soil
- Analyze data and finalize report
|
|